Using the wall-mounted door control, To open the door manually, Care of your opener – Chamberlain ATS 2113X User Manual

Page 24

Advertising
background image

24

To Open the Door Manually

The door should be fully closed if
possible. Pull down on the emergency
release handle and lift the door manually.
To reconnect the door to the opener,
press the door control push bar.

The lockout feature prevents the trolley
from reconnecting automatically. Pull
the emergency release handle down and
back (toward the opener). The door can
then be raised and lowered manually as
often as necessary. To disengage the
lockout feature, pull the handle straight
down. The trolley will reconnect on the
next UP or DOWN operation.

Trolley
Release
Arm

Trolley
Release
Arm

NOTICE

NOTICE

Emergency
Release
Handle
(Pull Down)

Emergency
Release Handle
(Down and Back)

To prevent possible SERIOUS INJURY or DEATH from a falling
garage door:

If possible, use emergency release handle to disengage

trolley ONLY when garage door is CLOSED. Weak or broken
springs or unbalanced door could result in an open door
falling rapidly and/or unexpectedly.
NEVER use emergency release handle unless garage

doorway is clear of persons and obstructions.
NEVER use handle to pull door open or closed. If rope knot

becomes untied, you could fall.

LOCKOUT POSITION

MANUAL DISCONNECT

POSITION

CARE OF YOUR OPENER

LIMIT AND FORCE ADJUSTMENTS:

Weather conditions may cause some
minor changes in door operation
requiring some re-adjustments,
particularly during the first year of
operation.

Pages 20 and 21 refer to the limit
and force adjustments. Only a
screwdriver is required. Follow the
instructions carefully.

Repeat the safety reverse test
(Adjustment Step 3, page 22) after
any adjustment of limits or force.

FORCE CONTROLS

LIMIT CONTROLS

Using the Wall-Mounted Door Control

Press the push button to open or close the door.
Press again to reverse the door during the closing
cycle or to stop the door while it’s opening.

MAINTENANCE SCHEDULE

Once a Month

Manually operate door. If it is unbalanced or binding, call a

trained door systems technician.

Check to be sure door opens & closes fully. Adjust limits and/

or force if necessary. (See pages 20 and 21.)

Repeat the safety reverse test. Make any necessary

adjustments. (See Adjustment Step 3.)

Twice a Year

Check chain tension. Disconnect trolley first. Adjust if

necessary (See page 7).

Once a Year

Oil door rollers, bearings and hinges. The opener does not

require additional lubrication. Do not grease the door tracks.

Advertising