Multi-function door control (optional) – Chamberlain ATS 2113X User Manual

Page 28

Advertising
background image

28

Multi-Function Door Control (Optional)

OPERATION OF THE MULTI-FUNCTION DOOR CONTROL

Press the push button to open or close the
door. Press again to reverse the door during
the closing cycle or to stop the door while
it’s opening.

Light feature

Press the Light button to turn the opener
light on or off. It will not control the opener
lights when the door is in motion. If you turn it on and then
activate the opener, the light will remain on for 4-1/2 minutes.
Press again to turn it off sooner. The 4-1/2 minute interval can be
changed to 1-1/2, 2-1/2, or 3-1/2 minutes as follows: Press and
hold the Lock button until the light blinks (about 10 seconds).
A single blink indicates that the timer is reset to 1-1/2 minutes.
Repeat the procedure and the light will blink twice, resetting the
timer to 2-1/2 minutes. Repeat again for a 3-1/2 minute interval,
etc., up to a maximum of four blinks and 4-1/2 minutes.

Lock feature

Designed to prevent operation of the door from hand-held remote
controls. However, the door will open and close from the Door
Control and the Keyless Entry Accessories.

To activate, press and hold the Lock button for 2 seconds. The
push bar light will flash as long as the Lock feature is on.

To turn off, press and hold the Lock button again for 2 seconds.
The push bar light will stop flashing. The Lock feature will also turn

off whenever the “learn” button on the
motor unit panel is activated.

LOCK

LIGHT

Lighted
Push Button

Lock
Button

Light
Button

To prevent possible SERIOUS INJURY OR DEATH from
electrocution:

Be sure power is not connected

BEFORE installing door

control.
Connect ONLY to 24 VOLT low voltage wires.

To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:

Install door control within sight of garage door, out of reach

of children at a minimum height of 5 feet (1.5 m), and away
from ALL moving parts of door.
NEVER permit children to operate or play with door control

push buttons or remote control transmitters.
Activate door ONLY when it can be seen clearly, is properly

adjusted, and there are no obstructions to door travel.
ALWAYS keep garage door in sight until completely closed.

NEVER permit anyone to cross path of closing garage door.

Opener Terminal Screws

2-Conductor
Bell Wire

Antenna

Opener Panel

Multi-Function
Door Control Panel
Terminal Screws

KG

KG

1

3

9

7

5

1

3

9

7

5

1

2

3

Door Control
Push Bar

Light Button

Lock
Button

LOCK

LIGHT

2

1

RED WHT

INSTALLATION

Locate door control within sight of the door at a minimum height
of 5 feet (1.5 m) where small children cannot reach, and away
from moving parts of the door and door hardware. If installing into
drywall, drill 5/32" holes and use anchors provided. For pre-wired
installations (as in new home construction), it may be mounted
to a single gang box. NOTE: After installation, a green indicator
light behind the cover will indicate proper connection. If not lit,
the Lock and Light features will not function (reverse wires to
correct).

Strip 1/4" (6 mm) of insulation from one end of bell wire and

1.

connect to the two screw terminals on back of door control by
color: white wire to 2 and white/red wire to 1.

Remove cover by gently pushing both thumbs against upper

2.

corners of cover on back side of door control. Fasten with
6ABx1-1/4" self-tapping screws (standard installation) or
6-32x1" machine screws (into gang box) as follows:

Drill and install bottom screw, allowing 1/8" (3 mm) to

protrude above wall surface.

Position bottom of door control on screw head and slide

down to secure. Adjust screw for snug fit.

Install top screw with care to avoid cracking plastic housing.

DO NOT overtighten.

Insert bottom tabs and snap on cover. (To remove cover after

mounting, gently pry at top with paper clip or small flat head
screwdriver.)

(Standard installation only)

3.

Run bell wire up wall and across

ceiling to motor unit. Use insulated staples to secure wire in
several places. Do not pierce wire with a staple, creating a short
or open circuit.

Connect bell wire to the opener terminal screws: white to 2 and

4.

white/red to 1.

Use tacks or staples to permanently attach entrapment warning

5.

label to wall near door control, and manual release/safety
reverse test label in a prominent location on inside of garage
door.

NOTE: DO NOT connect the power and operate the opener at this
time. The trolley will travel to the full open position but will not
return to the close position until the sensor beam is connected
and properly aligned. See Safety Reversing Sensor Instructions
beginning on page 15.