Switching Waveforms

Figure 1. Read Cycle No. 1 (Address Transition Controlled)

[16, 17]

Figure 2. Read Cycle No. 2 (OE Controlled)

[17, 18]

Figure 3. Write Cycle No. 1 (WE Controlled, OE HIGH During Write)

[19, 20]

PREVIOUS DATA VALID

DATA VALID

RC

t

AA

t

OHA

t

RC

ADDRESS

DATA OUT

50%

50%

DATA VALID

t

RC

t

ACE

t

DOE

t

LZOE

t

LZCE

t

PU

HIGH IMPEDANCE

t

HZOE

t

HZCE

t

PD

IMPEDANCE

I

CC

I

SB

HIGH

ADDRESS

CE

DATA OUT

V

CC

SUPPLY

CURRENT

OE

DATA VALID

t

HD

t

SD

t

PWE

t

SA

t

HA

t

AW

t

SCE

t

WC

t

HZOE

ADDRESS

CE

WE

DATA IO

OE

NOTE 21

Notes

16. Device is continuously selected. OE, CE = V

IL

.

17. WE is HIGH for read cycles.
18. Address valid before or similar to CE transition LOW.
19. Data IO is high impedance if OE = V

IH

.

20. If CE goes HIGH simultaneously with WE HIGH, the output remains in high impedance state.
21. During this period, the IOs are in output state. Do not apply input signals.