TROUBLEShOOTINg

Before Requesting Service: please follow this troubleshooting guide before contacting your dealer for assistance.

Caring for Finishes: For cleaning, a soft brush or lint-free cloth

should be used to prevent scratching the finish. A vacuum cleaner

brush nozzle can remove heavier dust. Surface smudges or an ac-

cumulation of dirt and dust can easily be removed by using a mild

detergent and slightly dampened soft cloth. An antistatic agent

may be used, but

never use abrasive cleaning agents. These will

damage the finish. Painted and high-gloss blades may be cleaned

in the same manner.

Blades: Wood finish blades should be cleaned with a furniture

polishing cloth. Occasionally, a light coat of furniture polish may

be applied for added protection and beauty.

Never Lubricate this Fan!

The precision motor at the heart of your Casablanca fan features

sealed bearings that are lubricated for life. Do not attempt to oil

the motor.

Changing Light Bulbs

Be sure to turn power to the fan OFF at the wall switch or circuit

breaker before changing light bulbs. Replace bulbs with same type

as removed from the fixture. Each fan is rated for a

maximum TOTAL

wattage of lighting.

Exceeding the rated maximum allowable wattage for the fan will

burn out the fan electronics module and void the warranty.

pROBLEm

pOSSIBLE REmEDIES

FAN WILL NOT START

Check main circuit fuses, circuit breakers, or wall switch position.

Check all wire connections, making sure the power is turned off during this inspection.

Check that reverse switch is not set in center of throw.

FAN WOBBLES OR ShAKES Be sure canopy pin is properly set into the slot on the ball.

EXCESSIVELY

Check the screws holding the blade holders to the flywheel (or direct drive motor). Tighten as necessary.

Check that bladeholders have not been bent during installation.

FAN NOISY DURINg

Check and tighten light fixture retaining screws, glass shade screws and/or the light bulb(s) as neccessary.

OpERATION

Tighten the blade to bladeholder screws.

Tighten canopy screws and mounting plate assembly.

Check and tighten blade holders to flywheel (or direct drive motor).

Make sure all screws in the motor housing are snug, but not overly tight.

Check that the wire nuts inside the canopy and switch housing are not touching the metal parts or have
fallen off the wire splices. Tighten or adjust as necessary.

BREAK-IN pERIOD

Let fan run at high speed for two (2) hours

DOES NOT RUN ON

If new, “break-in” may be required - run at higher speed for several days

LOW SpEED

pROBLEm

pOSSIBLE REmEDIES

..

3-SpEED

fan runs slowly in eiTher direcTion if roTaTion is sTarTed by hand; will noT reverse: Defective reverse switch; defective
capacitor; or open motor winding: Replace reverse switch assembly; replace PCB assembly; or replace motor unit.
fan will noT operaTe aT proper speeds or will noT operaTe aT any speed: Defective three-speed pull-chain switch assembly; or
defective capacitor: Replace three-speed pull-chain switch assembly; or replace PCB assembly.

For questions or to locate the nearest Casablanca Authorized Service Center

call toll free: 1-888-227-2178

or visit us on the web at: www.casablancafanco.com

Product SPecificationS

Model Name:

New Orleans Centennial

®

Model Number: 69xxD
Dimensions:

A = 26"

B = 28"

C = 3"

D = 13"

E = 5.6"

Weight:

36 lbs.

Motor:

XLP 2000

Blade Span:

46" or 54”

Blade Iron Pitch:

15°

No. of Blades:

5

Technology:

3-Speed

Airflow*:

6,005 cfm

Electricity Use*:

108 watts

Airflow Efficiency*:

58.1 cfm/watt

* Performance data is for fan only. No lighting wattage is

included. Measurements taken with 21” basic blades.