COLLAR

SWITCh

hOUSINg

3-SpEED OpTIONAL LIghT FIXTURE INSTALLATION

3-SpEED OpERATION

Pull-chain switches on the fan control the fan and lights.

Using the fan control pull-chain switch: Fan off at start.

First pull: fan ON, low speed

Second pull: medium speed

Third pull: high speed

Fourth pull: fan OFF

Using the optional light pull-chain switch: Light off at

start.

First pull: light ON

Second pull: light OFF

Direction of blade rotation is controlled by the reverse slide

switch on the side of the switch housing.

No changes in household wiring are required.

1. Refer to light kit instructions to assemble and attach your light

kit correctly.

2. Remove the two 8-32 screws from the switch housing cap.

3. Remove the plug from switch housing.

4. Install pull-chain switch and finger tighten collar on switch.

5. Connect one wire from pull-chain switch to the BLUE D1-Option

wire. Secure splice with a wire nut.

6. Connect other wire from pull-chain switch to BLACK wire from light

kit. Secure splice with a wire nut.

7. Connect WHITE wire from switch housing to WHITE wire from light

kit. Secure splice with a wire nut.

8. At the canopy, connect the BLACK and BLUE wires.

3-SpEED OpTIONAL WALL CONTROL W-40

The W-40 wall control provides four-speed control of fan from a convenient wall location.

The W-40 is designed to replace a standard wall switch and will fit wall boxes with a depth

of 2” or greater.

not for use with single pull-chain fan/light option wiring.

To install a W-40 wall control in place of an existing wall switch, follow the instructions

on the W-40 package.

Note: No rewiring is required if the fan is replacing an existing light fixture.
Operation of the fan from the wall switch is simple:

1. Turn knob to obtain desired speed setting.

R

3-SpEED OpTIONAL WALL CONTROL W-80

The W-80 wall control provides separate control of fan and light with two separate knobs

from a convenient wall location. The W-80 is designed to replace a standard wall switch

and wall boxes with a depth of 2” or greater. Requires two hot leads from wall box to ceil-

ing wiring box.
To install a W-80 wall control in place of an existing wall switch, follow the instructions

on the W-80 package.
Operation of the fan from the wall switch is simple:

1. Turn the upper knob to the desired fan speed.

2. Turn the lower knob to the desired light setting.

OFF

LO

MED

MED

HI

HI

OFF

MAX

CAUTION! Failure to set the pull-chain speed to hIgh can result in faulty operation of

the fan and damage to the W-40 wall control. To confirm fan is set to hIgh: Turn W-40

fan speed switch to ‘hI’ - set fastest fan speed with pull chain.

CAUTION! Failure to set the pull-chain speed to hIgh can result in faulty operation of

the fan and damage to the W-80 wall control. To confirm fan is set to hIgh: Turn W-80

fan speed switch to ‘hI’ - set fastest fan speed with pull chain.

noTe: If a separate circuit is used to control the lights from a wall

control, the BLUE D1-Option wire in the canopy should be connected

to that switch leg with the BLACK fan power wire.

3-Speed

REVERSE

SWITCh

OpTIONAL LIghT

pULL ChAIN

SWITCh

FAN & SpEED CON-

TROL

pULL ChAIN SWITCh