Bryant 394U User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

AIR DELIVERY PERFORMANCES

Air

Delivery

CFM

EXTERNAL STATIC PRESSURE AVAILABLE

Type L Motor 1 Type E Motor

Hi

Med

Med-Lo

Lo

Hi

Med

Med-Lo

Lo

700

0.67

0.56

0.70

800

0.57

0.38

0.80

0.48

900

0.41

0.72

1000

0.75

0.54

1100

0.70

0.30

1200

0.55

1300

0.78

0.30

1400

0.70

0.13

1500

0.59

1600

0.46

1700

0.33

tCFM approximately 13% less when rear air inlet used.

NOTE: Above data gives cfm under typical field applications (i.e. 125 volts).

Optional External Filter Rack Mounts on Either Side

R E A R O F F U R N A C E

■ 2 5

A C C E S S

LiNE-TO-LINE SCHEMATIC

UNIT WIRING DIAGRAMS

Advertising