Accoutrements HIGH ECONOMY GAS FURNACE 1200-103B User Manual
Page 6
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
After
the
piping
and
meter
have
been
checked
completely,
purge
the
eyatem
of
air,
00
NOT
bleed
the
air
inside
the
furnace.
Be
sure
to
relight
all
the
gas
pilots
on
other
appliances
that
may
have
been
extinguished
because
of
interrupted gas suppiy.
WIRING
■CAUTION
For
your
personal
safety,
turn
off
electric
power
at
service
entrance
panel
before
making
any electrical connections.
All
electrical
work
must
conform
with
local
codas
and
ordinances
or,
in
their
absence,
with
the
National
Electrical
Code, ANSI/NFPA 70-1981.
CAUTION
After
the
furnace
is
operating
with
filters
installed
and
all
cabinet
panels
are
in
place,
check
the
temperature
rise
through
the
unit
to
insure
it
is
within
the
range
specified
on
the
furnace
rating
plate.
If
it
is
not,
adjust
blower
speed
until
the
temperature rise is within specified range.
FIELD INSTALLED EQUIPMENT
Wiring to be done in the field between the furnace and devices
not
attached
to
the
furnace,
or
between
separate
devices
which
are
field
installed
and
located,
shall
conform
with
the
temperature
limitation
for
Тура
T
wire
[63^F
rise
(36^C)J
when
installed
in
accordance
with
the
manufacturer's
instructions.
Refer to wiring diagrams.
ELECTRICAL POWER SUPPLY
Run a separate 120 volt, 15 ampere, 60 Hz, AC circuit from a
separate
fuse
or
circuit
breaker
in
the
service
entrance
panel.
Locate
a
shut
off
switch
at
the
furnace.
Make
connections
from
this
switch
to
furnace
junction
box
as
shown
in
the
furnace
wiring diagram.
ELECTRICAL GROUNDING
A.
Recommended Grounding Method
When
installed,
the
furnace
must
be
electrically
grounded
in
accordance
with
local
codes
or
in
the
absence
of
local
codes,
with
the
National
Electrical
Code,
ANSI/NFPA
No.
70-1981. Use a #19 Awg copper wire from grounding lug or
green
ground
wire
on
the
furnace
to
a
grounded
connection
in
the
service
panel
or
a
property
driven
and
electrically grounded ground rod.
B.
Alternate Grounding Method
If
the
recommended
grounding
method
is
impossible,
permanently
ground
the
furnace
from
the
ground
connector
to
a
grounded
cold
water
pipe
using
a
separate,
green
colored,
insulated
conductor
of
appropriate
size.
THIS,
HOWEVER, IS NOT RECOMMENDED.
NOTE:
DO
NOT
ground
to
a
gas
supply
pjpe.
DO
NOT
connect
to
electric
power
supply
until
appliance
is
permanently grounded.
THERMOSTAT
Install
the
thermostat
in
accordance
with
instructions
packed
with
it.
Locate
the
thermostat
4-1/3
feet
from
the
floor
on
an
inside
wall
away
from
drafts,
warm
air
registers
and
floor
or
table lamps. Refer to furnace wiring diagrams for connections.
All
34V
wall
thermostats
have
heat
anticipators
to
compensate
the
thermostat
for
various
system
controls
and
allow
the
best
possible
cycle
rates.
Some
anticipators
are
fixed
and
require
no
adjustment.
However,
the
majority
of
wall
thermostats
have
adjusuble
anticipators
and
DO
REQUIRE
ADJUSTMENT
to
match
the
current
rating
of
the
gas
valve.
The
anticipator
setting should be 0.80A.
Failure
to
adjust
the
anticipator
lever
to
correspond
to
the
actual
current
draw
through
the
thermostat
will
cause
severe
short
cycling
if
set
too
tow
and
room
temperature
may
never
attain
the
thermostat
set
point,
and
if
set
too
high,
will
cause
room temperature to overshoot the set point.
FILTERS
All
models
are
shipped
with
filters.
See
Figure
11
for
sizes.
See Figure 13 and Figure 13 for filter location.
FIGURE 11 - FILTER SIZES FOR GAS FURNACES
Model
Size
1L85D43A
( 1) 18-3/4 X 20 P
1L115D48A
{!) 22-3/4 X 30 P
IL145D60A
(2) 13 X 20 P
P = Permanent type filter.
FIGURE 13 — FILTER LOCATION
Model IL85042A, IL115048A
Rear view with blower—
Filter Access Door Removed
BLOWER OPERATION
Alt
models
are
four
speed
direct
drive
models
equipped
with
a
heating-cooling
blower
relay,
and
whan
matched
with
the
appropriate
wall
themostat
offers
manual
blower
operation
from
the wall thanmstat for air circulation.
This
filter
is
the
permanent
high
velocity
type
hra
hair
which
may
be
washed
and
usad
over
and
ovar.
ifo
NOT
REPLACE
IT
WITH
A
FIBERGLASS
FILTER
OF
THE
SAME
SIZE. To raplaca filter, ravarsa tha above process.