2.2.1 Rack-Mount Gasket Installation

Installing the C

Y

RAQ in the landscape orientation requires 9U (15.5″) free rack space.

Prior to installing the C

Y

RAQ into a rack, the included gasket must be affixed to the

mounting plate.

IMPORTANT!
Unless requested at the time of purchase, the display is shipped with
gasket applied.
Skip to section 2.2.2.

However, in certain instances the mounting gasket may be shipped loose to allow for
increased installation flexibility in the case of custom applications. This permits
customers to then choose which mounting application best suits their environment—
panel- or rack-mount. Affixing the gasket to the back of the C

Y

RAQ’s enclosure is

recommended for panel mounting applications; while adhering directly to the mounting
plate is recommended for rack-mount applications.

The mounting gasket is a critical component to this monitor’s NEMA 4X rating for
watertightness—it must be installed correctly to meet this standard. It is also important to
note that the rack-mount installation procedure differs from the panel mount procedure.
Please read the instructions below carefully before installing the gasket.

1. On a flat surface, orientate the mounting plate

as depicted in Figure 2.

2. Arrange the gasket to match mounting plate.
3. Remove adhesive backing from Section A of

the gasket.

3

N

OTE

: It’s important to focus on aligning the

holes of gasket and mounting plate rather than
their respective edges.
4. Align center hole in gasket with center hole on

mounting plate, take care not to let other
portions of the gasket in Section A touch
mounting plate until aligned properly.

5. Carefully align and place the rest of Section A

holes, working out from center.

A

Center Hole

Figure 2: Gasket Installation

6. When done, firmly press down and smooth gasket in Section A.
7. Repeat process for each of the other three sides.

CyberResearch, Inc

.