Installation instructions – Cannon CHESTER 10540G User Manual

Page 31

Advertising
background image

31

SPACE FOR FIXING
The cooker can be close fitted below hotplate level. This requires a minimum distance
of 540mm between cupboard units of hotplate height.

When installing next to a tall cupboard, partition or wall, for a minimum distance of
400mm above hotplate level, allow a side clearance of at least 65mm.

The diagram below illustrates the minimum clearance between the cooker and
adjacent walls, cupboards etc.

The wall behind the cooker between the hotplate and 450mm above, and the width of
the cooker, must be a non-combustible material such as ceramic wall tiles.

If the cooker is to be fitted close to a corner on the left hand side, ensure that there is a
clearance of at least 50mm to allow the main oven door to open fully for when
removing oven shelves.

COOKER HOODS
If a cooker hood is to be installed, refer to the cooker hood manufacturers’ instructions
regarding fixing height.

INSTALLATION INSTRUCTIONS

65 mm Min

840 mm Min

400 mm Min

600 mm Min

540mm min

750mm min

400mm min

Advertising