4.6.1 Auto Media Sensor Calibration

Auto Media Sensor Calibration automatically establishes the optimum
sensing values for the media you are using in the printer.

;

Note:

Before calibrating, be sure the media sensor is set for the appropriate

media type, see Section 4.4.2; also, ensure that the Printhead Carrier
Assembly is latched down and the cover is closed.

To automatically calibrate the media sensor, proceed as follows:

1. With the desired media loaded, hold the

button while powering up

the printer. Continue to hold the button until the PAUSED Light turns
off then release it.


3. Next press the

button. The printer will feed approximately ten

inches of media to calculate the TOF Delta and Low values to be
used.


4.

Upon completion, one of the following Indicators will flash five times
to denote the result of the auto calibration attempt:

PAUSED Light = Successful calibration. Proceed to Step 5.

FAULT Light = Unsuccessful calibration. Proceed to Section 4.6.2.


;

Note:

If you wish to discard the changes and revert back to the
previous calibration simply turn off the printer before Step 5.


5. Now save the changes and resume

by pressing the

+

buttons simultaneously and briefly. Wait until the PAUSED

Light goes off.