Electrical connection

220-240 V - using fixed power supply line with plug.

(The unit should only be connected up by an authorized electrician).

Your appliance must be connected to fixed wiring via the use of a double

pole swiched fused spur outlet with or without pilot lamp.

We strongly recommend the appliance is connected by a qualified

electrician who is a member of the NICEIC who will comply with the IEE
and any local regulations.

NOTE: the terminology “DOUBLE POLE” means that both the live

and neutral supplies are swiched and disconnected at the same time.

The terminations labelled SUPPLY are for the connection for the internal

house wiring and the terminations labelled LOAD are for the appliance.

IMPORTANT

The wires of the mains lead supplied with this appliance are

coloured in accordance with the following code:

Blue-Neutral

Brown-Live

As the colours of the flexible cord of this appliance may not

correspond with the coloured markings identifying the terminals in

your plug, proceed as follows: The whire which is coloured brown

must be connected to the terminal which is marked with the letter
L or coloured red.

The wire which is coloured blue must be connected to the terminal

which is marked with the letter N or coloured

black.

- - -BLUE

BROWN