Installation

Permanent fitting In kitchens:

Before you use your new FAVORIT dish­

washer, you should make the following

checks:

Removal of packing

During transit the outlet hose is atta-
dned to the machine at the underside,
with plastic tape. Tilt the machine badt-
wards and remove the plastic tape.

When returning the machine to its ori­
ginal position, make sure that the outlet

hose lies freely against the left hand

side of the appliance and is not crushed
on the floor. The two baskets are secu­

red by wooden blocks, inside the washer

tub.

Open the door and remove supporting

wooden blodcs and corrugated card­

board packaging.

The lower left hand basket assembly is
secured by transparent adhesive tape

inside the lower basket.

Pull off adhesive tape.

Dimensions;

With worktop

Without worktop

Height 85 cm

Width 60 cm

Depth 60 cm

Height 82 cm

Width 59.5 cm

Depth 57.5 cm

The appliance must stand level — If In
doubt use a spirit — level (maximum

permissjble deviation 2°). If necessary

adjust front feet.

Welg^i

Free standing model approx. 72 Kg net

Built-iiVunder model approx. 68 Kg net

The Appliance has adjustable feet at the
front and fixed rollers at the rear.

Seek advice from your Specialist
Retailer from whom you purchased the
appliance.

Dimensions of Decor panels
(for built-under model)

Door

Lower panel

457.5 X 589.5-radius 11

120.5 X 589.5-radius 11

Electrical connections

A. C. Current

220 V

(U. K.-version240V)

Connected load

3.4 kW

(U. K.-version 3.1 kWJ

Plus 13 amp —fused

Green and yellow

Earth

Blue

Neutral

Brown

Live

As the colours of this mains lead of this

appliance might not correspond with the
coloured markings Identifying the ter­
minals in your plug, connect as follows:

The green and yellow wire must be
connected to the terminal In the plug

which is marked with the letter "E" or by
the earth symbol or coloured green or

green and yellow. The wire which is
coloured brown must be connected
to the terminal marked with the letter
"L" or coloured red. The wire which is
coloured blue must be connected to the

terminal with the letter "N" or coloured

black.

Wafer supply

The high pressure hose (Va" = 10 NW,

1.55 m long] with V«" hose coupling com­
plete with sealing washers Is supplied. We

recommend not to use other washers

which may be of inferior quality. It is suffi­

cient to tighten the nuts by hand but if a
spanner is used proceed very carefully.