In case of trouble, No output, Controls have no effect – Ashly LIMITER/COMPRESSORS CL-100 User Manual

Page 16: Excessive hum or noise

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

The concept of stereo operation is sometimes confusing, but it is less difficult

to understand if you keep a few basic rules in mind

When the switch is in:

1. Gain reduction is identical for both channels. Any gain reduction that

occurs on channel 1 will also occur on channel 2 and vice-versa

2. The TIE switch overrides an individual channel s IN/OUT switch.

For example ifCh. lis switched OUT but Ch. 2 and the TIE switch
are both IN, then any limiting action which occurs onCh.2 will also
occur on Ch. 1 even though Ch. 1 is switched OUT. The Ch. 1 GAIN
REDUCTION meter will verify that this is true.

3. When both channels are switched IN and the STEREO TIE switch is

IN, either channel can cause gain reduction on both channels. In other

words, whichever channel exceeds the threshold first will cause an
equal gain reduction on both channels.

4. When in the STEREO TIE mode, the attack and decay characteristics

of both channels will be determined by whichever channel actually
caused the gain reduction. If both channels simultaneously receive an
above-threshold signal, then the attack tíme will be determined by

the channel with the fastest ATTACK TIME setting and the release
time will be determined by the channel with the slowest RELEASE

TIME setting.

5. If you want to deliberately make one channel a slave to the other,

simply switch OUT the channel that is to be the slave, switch IN the
master channel, and switch IN the STEREO TIE.

28

ABHLY

IN CASE OF TROUBLE

NOTEL* Unshielded cables, improperiy wired connectors, and cable with broken

strands of wire rattling around are very common problems. Use good quality cables

with good quality, correctly wired connectors.

NO OUTPUT

Check AC Power. Is the power switch on? Check input and output

connections—are they reversed? Are you sure you have an input signal?

CONTROLS HAVE NO EFFECT

Is the LIMIT EN/OUT switch IN? Perhaps the RATIO control is set too

low to produce an audible effect or the input level is below threshold. Is the

THRESHOLD LED lighting up? If not, increase the GAIN control. Do not

expect to hear any effect when the input level to the CL-50E is below

threshold, since the unit is simply a linear amphfiier at those levels.

WHEN USING HEAVY COMPRESSION, BACKGROUND NOISE

tS NOTICEABLE DURING QUIET SECTIONS OF THE PROGRAM

As defined in the section on compression, quiet program material is

effectively made louder while loud peaks are made quieter. When the

program source is thus raised in volume, its noise floor is also raised in

volume by a proportionate amount. This is not a defect in the compressor/

limiter, but an unavoidable side effect of the gain altering process. If the noise

becomes a problem, the solutions are to either clean up the program source, or

use less compression.

EXCESSIVE HUM OR NOISE

Hum is often caused by a “ground loop” between components. T

17

using

the suggested balanced input and output hookups if the other pieces of

equipment used in conjunction with the CL-SOE have balanced inputs and

outputs. Noise can also be caused by insufficient drive levels. Make sure you

are sending a nominal 0 dBV line level signal to the unit. □

ABHiy

29

Advertising
This manual is related to the following products: