Trouble Shooting Guide (cont.)

Probably Cause #4 ...............Individual jet is closed.
Action ....................................Turn the outer jet housing clockwise to turn jet on.

Low water flow

Probable Cause #1 ...............Dirty Filter.
Action ....................................Remove filter cartridge and clean.

Probable Cause #2 ...............Closed gate valves or blocked lines.
Action ....................................Open all gate valves.

Probable Cause #3 ...............Low voltage or incorrect voltage.
Action ....................................Have a Licensed Electrician check the line voltage.

Spa is leaking

Probable Cause #1 ...............Loose connection.
Action ....................................Hand tighten all disconnects and fittings. Check

joints and unions.

Motor does not run

Probable Cause #1 ...............No power to motor.
Action ....................................Check power switches and circuit breakers. Check

motor plug where plugged into control box.

Probable Cause #2 ...............Pump jammed from foreign matter in impeller.
Action ....................................Call dealer for recommended action.

Probable Cause #3 ...............Motor overheats on hot days while filtering.
Action ....................................Reprogram your controls to cycle during the

coolest parts of the day and on shorter cycles.
(see programming instructions).

Motor runs hot

Probable Cause #1 ...............Pump ran dry.
Action ....................................Call dealer for recommended action.

Probable Cause #2 ...............Restricted suction lines.
Action ....................................Make sure all valves are open/clear suction of

debris.

Probable Cause #3 ...............Improper ventilation
Action ....................................Insure that vents on side of spa are free and clear

of any debris or landscaping. Spa should also be
located an adequate distance from any walls or
fencing for good ventilation.

Note: These motors will feel hot to the touch. This is
normal. The Overheat Sensor will turn the motor off if there
is an overload or high temperature problem.