Installation of the beer keg, Installation of the keg coupler, Installation of the co2 air line hose – Avanti BD555 User Manual

Page 10: Connecting the beer tower to coupler, How to tap a keg of beer, Opening the co2 cylinder main valve, Adjusting the co2 regulator

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Of The Beer Keg

Position the keg stand directly in front of the open door. Using keg handles only, carefully lift the

beer keg onto the stand. (See Figure 5)

To place the beer keg and stand inside the cabinet, brace your knees behind the keg stand. Lift

the front of the keg just enough so the front edge of the stand is resting on the front edge of the

Beer Dispenser bottom cabinet. (See Figure 6)

- Grasp the keg stand front handles and slide it all the way into the cabinet.

Fig. 4

Fig. 5

Fig. 6

Installation Of The Keg Coupler

• Insert the keg coupler provided into the locking neck of the beer keg and turn it clockwise to lock

into position, making sure the keg coupler is in the closed position. (See Figure 7)

Installation Of The CO

2

Air Line Hose

• Attach the open end of the red hose to the hose barb connection on the keg coupler. Secure hose

by using the plastic snap provided, using pliers to tighten clamp.

Connecting the beer tower to coupler

Make sure the washer is properly inserted into the wing nut.

Place wing nut into the top of the coupler turning until tight.

How To Tap A Keg Of Beer

Make sure the beer tower faucet is in the closed position.

Pull tapping handle out and press downward until it locks into position. (See Figure 8) The keg is
now tapped.

Opening The CO

2

Cylinder Main Valve

Before doing that, make sure the secondary shut-off valve is closed, as shown in figure 9. To
open the main CO

2 cylinder valve, slowly turn the main valve counter-clockwise until fully open.

Notice the needle on the gauge start to climb.

Adjusting The CO

2

Regulator

The gauge monitors low internal keg pressure and should be adjusted to read between 10-12
psi/lbs. (See Figure 10)

In order to do that:

1. Release adjustment lock nut marked 2.

Using a flat screwdriver, turn regulator screw marked 3. If increased low pressure is sought,
rotate screw clockwise. By rotating it counter clockwise, low pressure will be decreased when
the required operating pressure is attained, retlghten lock nut 2.

Open secondary shut off valve to let C02 flow into the keg.

2.

3.

Fig 7

F,g 8

Fig 3

Fig 10

Advertising