Datamax E-Class E-4304 User Manual

Page 30

Advertising
background image

20

E-4203/E-4204/E-4304

9) CONTROL CODES

Allows code selection listed in
Programmer’s manual.

Possible Values:

*

(STD) STANDARD CODES

(ALT) ALTERNATE CODES

10) CONT FORM LENGTH

This command sets the page size (label
length) when the printer’s ‘SENSOR
TYPE’
is set to continuous media.

Possible Values:

Range: 0 – 9999; default = *100
Units: .01 inch

11) OOS MAXVOLT

Sets the sensor reading that can
indicate OOS, (out of stock
condition).

Possible Values:

Range: 0 – 16; default = *2
Units: 0.1 volt

12) TOF GAIN

Sets Top of Form (TOF) Gain value.

Possible Values:

Range: 0 – 15; default = *10

13) TOF DELTA

Sets minimum change in the sensor
reading required to recognize a
“Gap” or Mark”.

Possible Values:

Range: 0 – 50; default = *10
Units: 0.1 volt

14) TOF LOW

Sets the minimum sensor reading for
paper (EDGE) or mark (Reflective).

Possible Values:

Range: 0 – 50; default = *0

Units: 0.1 volt

15) LABEL WIDTH

Sets the label width.

Possible Values:

Range: 75 – 410; default = *410
Units: .01 inch

16) Scalable Font

Sets the number of 4K Byte blocks
allocated for scaleable fonts.

Possible Values:

Range: 0 – 255; default = *64