Datamax E-Class E-4304 User Manual

Page 32

Advertising
background image

22

E-4203/E-4204/E-4304

4.4.3 Example of Changing Baud Rate

The following is a step by step example for modifying the Printer Setup.
Although this example will show how to modify only the Baud Rate value from a
default of 9600 bps to 19200 bps the same procedure can be used to change any
of the printer’s menu items.

Note:

It is recommend that the Printer Setup Mode is not executed with the
printer in Peel Mode or the optional Present Sensor enabled. Depending
on label size this can cause unpredictable results.

1.

With printer off and properly loaded with media press and hold the

button while powering up the printer. Continue to hold the

button until the PAUSED light turns off then release.

2.

Press and hold the

button and count 7 flashes of the FAULT light

then release. The following printout should be showing:

3.

Press the

button once to increment to the 19200 bps value. The

following printout should be showing:

4.

At this point you will accept the current values for “test” and exit the
Printer Setup Procedure by pressing the

+

buttons

simultaneously.

Note:

If you wish to discard your changes and revert back to the previous
values simply turn off the printer before Step 5.

5.

Now you can save your changes and resume

by again

pressing the

+

buttons simultaneously. Wait about 15 seconds

for

to begin.

Advertising