17 interrupt stop under windows – ADLINK cPCI-7249R User Manual

Page 55

Advertising
background image

C/C++ Libraries 47

@ Argument

cardNo: card number which the DIO will be reset.

c1:

If the interrupt source is set as internal timer

source, this value is the frequency divider of

Timer#1.

c2:

If the interrupt source is set as internal timer

source, this value is the frequency divider of

Timer#2.

ctrlValue:

the value for INT mode setting. The value can

be set for INT1 is

INT1_OFF, INT1_P1C0,

INT1_P1C3C0, or INT1_EVENT_IRQ.

The value can be

set for INT2 is

INT2_OFF,

INT2_P2C0,

INT2_P2C3C0,

or

INT2_TIMER_IRQ. Please refer to section 3.3.4

for detailed description.

hIntEvent:the handle of the event for interrupt signals.

@ Return Code

ERR_NoError

5.17 Interrupt Stop under Windows

@ Description

This function is only available in Windows 95/98 driver. This function is used
to disable the interrupt signal generation.

@ Syntax

C/C++ (Windows 95)

void W_7248_INT_Stop (U16 cardNo)

void W_7249_INT_Stop (U16 cardNo)

void W_7296_INT_Stop (U16 cardNo)

Visual Basic (Windows 95)

W_7248_INT_Stop (ByVal cardNo As Integer)

W_7249_INT_Stop (ByVal cardNo As Integer)

W_7296_INT_Stop (ByVal cardNo As Integer)

@ Argument

cardNo: card number which the DIO will be reset.

@ Return Code

ERR_NoError