FALSE ALARMS

• Verify the connection between Sensor Pad and Nursery Unit. Unplug and reconnect

the cord.

• Make sure there is no bedding between the mattress and the Sensor Pad.
• If the crib has a spring or slat base, place a hardboard between the crib base and

the Sensor Pad measuring at least 33 cm x 33 cm and 6 mm thick.

• Make sure the Sensor Pad is positioned as described under the setup requirements.

Sensitivity may need to be adjusted, refer to step 5.3.

ALARM WILL NOT SOUND

• Avoid contact with the crib when the monitor is ON.
• Place the crib near a solid supporting wall to avoid Sensor Pad from detecting

movement from outside the crib.

• You may need to increase the sensitivity, refer to step 5.3.

NO SOUND IS BEING TRANSMITTED

• Ensure that both units are switched ON.
• Check that the sound has not been turned down on the Parent Unit. Increase

the volume level on the Parent Unit, refer to step 5.5.

• Check on the Parent Unit screen to see if the monitor is in temporary MUTE mode

instead of ON mode. Deactivate the temporary MUTE function, refer to step 5.6.

• If there is no power to any unit check/replace the batteries, recharge the Parent Unit

& check the AC Adaptors are working. Change electrical outlets if required.

• Bring the Parent Unit and Nursery Unit closer together.

NURSERY UNIT POWER ON INDICATOR (GREEN LIGHT) DOES NOT LIGHT UP

• Turn the switch behind the left wing ON.
• Check connections or change to another electrical outlet.

WEAK RECEPTION

• Bring units closer together.
• Change the position of one or both units.
• Place units on a flat surface away from baby’s reach.
• Replace the batteries or recharge Parent Unit.

STATIC, DISTORTION, INTERFERENCES
(FROM OTHER MONITORS, WIRELESS PHONES, WALKIE-TALKIES, ETC...)

• Rotate the Parent Unit or move it away from source of interference.
• Try a different channel, refer to Step 4.

FEEDBACK (LOUD NOISES EMITTED FROM THE PARENT UNIT)

• Move the units farther apart (at least 3 meters apart).
• Decrease the volume on the Parent Unit.

THE PARENT UNIT SCREEN IS BLACK (PARENT UNIT IS OFF)

• Turn the Parent Unit back ON by pushing and holding the power button.
• Replace the batteries or recharge the Parent Unit.

If you experience a problem that is not noted in this manual,
please do not return the product to the store. If you are not completely
satisfied or have any questions:

United States and Canada: please contact us at: [email protected]

Other countries: please contact your local Distributor.

We may have a simple solution to your problem.

LIMITED WARRANTY

Angelcare

®

warrants to the original owner of this product that Angelcare

®

rechargeable,

movement and sound monitor (model AC403) is free from any material and workmanship
defects, for a period of one (1) year (rechargeable batteries not included) from the date
of the original purchase. If this monitoring system fails to function properly when used as
directed under normal conditions within the one year period, Angelcare

®

will either repair

or replace the product, at our discretion, free of charge. Please contact your distributor.

The product must be accompanied by a proof of purchase, either a bill of sale or other
proof that the monitoring system is within the warranty period. Angelcare

®

will bear the

cost of repairing or replacing the product and shipping it back to you.

This warranty does not apply to a product which has been damaged as a result of
improper maintenance, an accident, improper voltage supply or any other form of
misuse. The warranty is also void if the owner repairs or modifies the product in any
way. Angelcare

®

is not liable for any incidental or consequential damages with regard

to this product. The warranty also excludes any liability other than what is stated above.
No other warranty is given.

LEGAL RIGHTS VARY FROM COUNTRY TO COUNTRY. SOME COUNTRIES DO NOT ALLOW
THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO
THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.

WE ARE NOT IN ANY WAY RESPONSIBLE FOR ANY OUTCOME RESULTING FROM
THE USE OF THIS PRODUCT.

IMPORTANT

!

This Angelcare

®

monitor is a personal care product. Please do not return this product

to the store. If you have questions or need help, please call your distributor before
returning this product.