Mls-10ex level switch – Babbitt Liquid Level Gauge User Manual

Page 10

Advertising
background image

MOUNTING

The MLS-9EX are simply mounted to the level gage chamber using stainless steel band clamps.
The switch must be originated properly, switch is marked “TOP”. It is adjustable the full length of the
level chamber. To set up desired contact state follow the steps below:

RISING LEVEL ALARM

Common

(NC)

(NO)

TERMINAL

2

3

1

FALLING LEVEL ALARM

Common

(NC)

(NO)

TERMINAL

2

1

3

After the switch is mounted and wired, it needs to be set to the desired state for rising or falling
level as noted above. This is easily accomplished by either manually pushing the float past the
highest switch or filling the gage chamber with fluid until all switches are properly set.

Note: Refer to Appendix B for pump up/pump down instructions.

MLS-10EX LEVEL SWITCH

The 10-EX level switch is a DPDT high current device used to control pumps, alarms, solenoids,
etc. The 10-EX is a cam-activated switch designed for use with the LG series magnetic level
gages. The switch can be factory set for either a rising or falling condition depending upon the
specific application. The 10-EX meets all Class 1, Div. 1 codes and the internal switches are
UL/CUL listed. For more information on specific applications contact the Babbitt Engineering
department at (713) 869-7259.

ELECTRICAL SPECIFICATIONS

10 AMP Max. @ 125/250 VAC

½ AMP Max. @ 125 VDC

3.0 AMP Max. @ 30 VDC Resistive

2.0 AMP Max. @ 30 VDC Inductive

Contact Configuration: DPDT

Advertising