Bimba PCS User Manual

Page 10

Advertising
background image

www.bimba.com

Technical Assistance: 800-44-BIMBA

10

The following table shows recommended tubing sizes. Oversized tubing will degrade
positioning repeatability.

Bore Size

Tubing Size

PFC

PTF

1-1/16" (09)

5/32" OD

1-1/2" (17)

1-1/2" (098/196)

5/32" OD

2" (31)

2" (247/494)

1/4" OD

Air line connections are described in the illustrations below. Instructions follow. Also
consult the Appendix for air and electrical connections to PFCN, PFC, and PT.






















• Connect the 70 -80 psi supply air to the center port of the valve manifold.
• Connect the valve manifold retract port (the port directly to the left of the

center port when the manifold is facing you) to the rod end of the cylinder.

o

For PTF rotary actuators, connect this to the port on Body “A” for

single rack models (left side when the PTF shaft is facing toward you),
or connect to bodies “A” and “D” for double rack models (lower left
and upper right when the PTF shaft is facing toward you).

• Connect the extend port (the port directly to the right of the center port when

the manifold is facing you) to the cap end of the PFC cylinder.

o

For PTF rotary actuators, connect this to the port on Body “B” for

single rack models (right side when the shaft is facing toward you), or
connect to bodies “B” and “C” for double rack models (upper left and
lower right when the shaft is facing toward you).

Do not turn the air supply on at this time.

Air hose connections for enclosed controls PCS models 1, 2, 3

Air hose connections for enclosed controls PCS models 5, 7, 8

Air hose connections for option N PCS controls

(without enclosures)