Bimba PCS User Manual

Page 12

Advertising
background image

www.bimba.com

Technical Assistance: 800-44-BIMBA

12

Option Q
Connect the Quick Connect power cable (2 meter model PCS-CBL-PWR or 5
meter Model PCS-CBL-PWR-X) to power. Connect the other end of the cable
using the following color codes: +24 VDC-Brown, Ground-Blue, the other wires
are not used.

Quick Connect Wire Color Codes

Power cable PCS-CBL-PWR

Command Cable PCS-CBL-CMD

Color Pin

Description

Color

Pin

Description

Brown 1

Positive Brown 1

Input

White 2

N/C

White 2

@

Position

Blue 3

Negative

Blue 3

Ground

Black 4

N/C

Black 4

Current

Position

Green/Yellow 5 N/C

Gray

5 N/C

Pink

6

N/C

Do not allow the supply voltage to vary outside of the 23.5 to 24.5 voltage
specification, as this will degrade system response and performance
significantly.


5.

CONNECT THE FEEDBACK CABLE













Standard Enclosure
Connect the feedback cable from the actuator to the PCS. The OD of the cable
must be between 0.114 inch and 0.250 inch. If the actuator is equipped with a
plug connector, utilize accessory cable C5 or C5X. If the actuator has a pigtail
lead, attach a longer cable between the actuator and the PCS observing the color
standards shown in the table below. Pass the cable through the bulkhead strain
relief and connect the individual wires to terminal block TB2 on the PCS board.

Wire Function From

Feedback Device

Wire Color 3

Pin Connector

(C5 or C5X)

Wire Color

Pigtail Lead

PCS

Terminal Block

TB2

Input (Excitation Voltage)

Blue

Red

A

Feedback Signal

Brown

White

B

Ground Black

Black

C

Shield

Shield N/A Shield

For PFCN only

, power to the probe MUST come from 24 VDC supplied

to the PCS control, and NOT the 10 VDC that the PCS produces from
terminal A of TB2.

For PFCN only

, If the Q (quick connect) option was selected, the lead

from the connector to terminal A of TB2 must be removed and the lead
reinserted into the +24VDC terminal of TB1.

For PFCN only

, always insert a jumper between TB1 ground and TB2

terminal C.

See PFCN ELECTRICAL AND PNEUMATIC CONNECTIONS
illustration in APPENDIX A.

Advertising