Cc20e series airline respirator user manual, Operations, 3operations – Bullard CC20E User Manual

Page 3: Breathing air pressure, Breathing air supply hoses and hose fittings, Cc20e breathing air pressure table

Advertising
background image

CC20E Series airline respirator

User Manual

3

Operations

Operations

Breathing air Pressure

Air pressure must be continually monitored at the point-of-attachment while operating
this respirator. A reliable air pressure gauge must be present to permit you to
continually monitor the pressure during actual respirator operation.

The Breathing Air Pressure Table defines the air pressure ranges necessary to provide
CC20E

Breathing air Supply Hoses and Hose Fittings

CE approved Bullard air supply hose(s) MUST be used between the breathing tube
connection fitting on the wearer’s belt and the point-of-attachment to the air supply
(Figure 2). When connecting lengths of E10 hose together, only use Bullard V11 hose-to-
hose adaptors. Secure connection(s) until wrench-tight and leak-free. Total connected
hose length and number of hoses MUST be within the ranges specified on the Breathing
Air Pressure Table. The maximum working pressure of E10 hoses is 500 psi (34 bar).
The breathing tube connection fitting MUST be secured to the belt that is supplied with
this respirator. Securing the air entry connection fitting helps prevent the air supply hose
from snagging, disconnecting or pulling the respirator hood off your head.

CC20E Breathing air Pressure Table

This table defines the air pressure ranges necessary to provide

CC20E Series respirators with a volume of air that falls within the required range.

The respirator provides an air flow of 240-325 lpm to the user. The minimum

length of air supply hose is 10 meters, and the maximum length is 20 meters.

1

2

3

4

air SOUrCE

BrEaTHing

TUBE

aSSEMBLY

HOSE LEngTH

POinT OF

aTTaCHMEnT

PrESSUrE

Bar (PSig)

Stationary

or

portable

V30/V33E

10 meters
20 meters

1.2 - 1.5 17 - 22
1.4 - 1.7 19 - 25

V39E

10 meters
20 meters

0.7 - 0.8 9 - 12

0.9 - 1.0 12 - 15

POinT-OF aTTaCHMEnT(POa)
The point-of-attachment is the point at which the air supply hose connects to the air source. A pressure gauge
attached

to the air source is used to monitor the pressure of air provided to the respirator wearer.

Warning

Failure to supply the minimum required pressure at the point-of-attachment

for your hose length and type will reduce airflow and may expose you to life-

threatening conditions, diseases or death.

Warning

Be certain your employer has determined that the breathing air source provides clean breathable air. This

respirator must be supplied with clean breathable air at all times. Do not connect the respirator’s air supply

hose to nitrogen, oxygen, toxic gases, inert gases or other unbreathable air sources. Check the air source

before using the respirator. Failure to connect to the proper air source may result in serious injury or death.

POinT-OF-

aTTaCHMEnT

Bullard CC20E Series airline respirator

Suitable After-Cooler/

Dryers with filters and

carbon monoxide monitor

as required

Breathing Air Compressor

with storage tank

Compressed Breathing air System

POinT-OF-aTTaCHMEnT

Bullard air

Supply Hose

Figure 2

Bullard 41 Series Airline Filter