7

Sizing and installing Hard Hat in TiCHE Hood


1. Assemble and adjust the standard TGE Bullard hard hat suspensions or the optional
TGRE ratchet suspensions by following the directions on instruction sheet attached to
headband on hard hat. Read all hard hat warning labels and instructions. The following
Bullard hard hat models are approved for use with CC20E Series respirator hoods:
5100E and 5100RE.
2. If desired, install and adjust optional ES42 hard hat chin strap.
3. Before inserting hard hat into hood, remove the adhesive-backed Velcro

®

strip attached to the Velcro piece that is sewn into the hood.
4. Peel the backing off the Velcro tab and apply it to the inside center rear of the hard hat,
about 1/4” from the edge.
5. Insert hard hat into respirator hood with cap visor facing front of hood. Tuck cap visor on
top of front elastic band sewn into hood (see Figure 7).
6. Loop the Velcro strip sewn inside the hood around the back of the cap and affix it to the
corresponding Velcro tab previously installed inside the hard hat in step 4 (see Figure 8).
7. Remove the plastic from lens of respirator hood. If desired, apply optional 20LCL adhesive-
backed lens covers designed to protect the respirator’s plastic lens. Apply 2-3 lenses at
a time. When a lens cover becomes soiled, remove it by pulling tab at edge of lens cover
to clear your vision.

installing Breathing Tube assembly

1. Remove nylon clamp from open end of breathing tube (see Figure 9). Do not
remove foam from inside the breathing tube. The foam helps reduce the noise
level of incoming air.
2. Insert breathing tube approximately five inches into hood’s air entry sleeve (see
Figure 10).
3. Install nylon clamps over air entry sleeve and breathing tube, inserting clamp
locks through two holes in plastic anchorplate that is sewn into hood. Locks
should face away from user’s neck (see Figure 11).
4. Engage clamp locks and squeeze together with slip joint pliers until tight.

CC20E Series airline respirator

User Manual

5

Figure 8

Front
elastic band

Velcro strip

Velcro tab

Window

Velcro Strip

Figure 7

To tighten

To remove

To tighten

Figure 10

Figure 9

Figure 11

Advertising