Refer ence man ual, Wir eless fuzzyscan – Cino L780BT HC User Manual

Page 75

Advertising
background image

W

ir

eless FuzzyScan

R

efer

ence Man

ual

Configure Your FuzzyScan

68

Programming Procedure
[Data Verifier]

Scan “Program” to enter the programming mode.

Scan “Verifier Control” and set bar code symbology to “48

(Interleaved 2 of 5).

Scan “Identified Data Length” and set the length to “16”.

Scan “1st Identified Character” and set the identified

position to “00”, then set the identified character to “39

(Hex Code of 9).

[Data Formatter]

Scan “Formatter Control” and set bar code symbology to

48”.

Scan 1st Insertion” and set the identified position to “06”,

then inserted characters to “09” (Hex Code of TAB), “53

(Hex Code of S), “4E” (Hex Code of N).

Scan “2nd Insertion” and set the identified position to “12”,

then inserted character to “09”. In the final, you must scan

FIN” (Finish) code to terminate this selection.

Scan “3rd Insertion” and set the identified position to “16”,

then inserted character to “09”. In the final, you must scan

FIN” (Finish) code to terminate this selection.

[Data Replacer]

Scan “Replacer Control” and set bar code symbology

to “48”.

Scan “1st Replacement” and set the identified position

to “00”, then replaced character to “41” (Hex Code of

A).

[Data Organizer]

Scan “Organizer Control” and set bar code symbology

to “48”.

Scan “1st Organization” and set the identified position

to “16”, then set the data transmission to “0” (forward).

Scan “2nd Organization” and set the identified position

to “17”, then set the data transmission to “1

(backward).

Scan “END” (Exit) to terminate the programming.

[Important Notice]

Please note that Condensed DataWizard will follow the

preset working flow as below:

Verifier  Formatter  Replacer  Organizer

So when you set the identified position in Data Organizer,

you must consider the inserted data which you already set

via Data Formatter.