Information menu – Clay Paky ALPHA SPOT QWO 800 “ST” User Manual

Page 21

Advertising
background image

System
Version

Board Revis. Hw.rv.
CPU brd x.x.x x.x
com.dev x.x
0: PT-3f x.x x.x
1: 6-Ch x.x x.x
2: 8-Ch x.x x.x
3: 6-Ch x.x x.x

Board

Diagnost.

Board Status Err%
0:PT-3f Good 0.00
1:6-Ch Good 0.00
2:8-Ch Good 0.00
3:6-Ch Good 0.00

Lamp

Strikes

Total

XXX

Partial XXX

Reset...

21

ALPHA SPOT QWO 800 &

ST

SYSTEM ERRORS
Shows a list of warnings and messages relevant to errors occurred since
the fixtures switching-on.
1) Pressing

F

you are allowed to reset the SYSTEM ERRORS list.

A confirmation message (Are you sure you want to clear error list ?)
appears on the display.

2) Select YES to reset the list or NO to go back.

FIXTURE HOURS
Used for displaying projector operating hours (total and partial).
1) Press

F

- Hours total and partial appears on the display.

Total counter
Counts the number of projector working life hours (from manufacture to date).
Partial counter
Counts the number of partial projector working life hours since the
last reset to date.

2) Press

F

to reset partial projector working hours a confirmation

message (Are you sure?) appears on the display.

3) Select YES to reset partial projectors counter or NO to keep the

current setting and return to the top menu level.

LAMP HOURS
Used for displaying the lamp working hours (total and partial).
1) Press

F

- Hours total and partial appears on the display.

Total counter
Counts the number of projector working hours with the lamp on (from
manufacture to date).
Partial counter
Counts the number of lamp working hours since the last reset to date.

2) Press

F

to reset partial lamp working hours, a confirmation message

(Are you sure ?) appears on the display.

3) Select YES to reset partial counter or NO to keep the current setting

and return to the top menu level

LAMP STRIKES
Used for displaying the number of times the lamp was turned on (total and
partial).
1) Press

F

- the number of times the lamp was turned on (total and

partial) appears on the display.
Total counter
Counts the number of times the lamp was turned on (from manufacture
to date).
Partial counter
Counts the number of times the lamp was turned on since the last
reset to date.

2) Press

F

to reset partial lamp strikes hours, a confirmation message

(Are you sure ?) appears on the display.

3) Select YES to reset partial counter or NO to keep the current setting

and return to the top menu level

SYSTEM VERSION
Used for displaying the software and hardware version of each board
installed in the projector.
CPU brd (CPU board)
0: PT-3f (Pan / Tilt board)
1: 6-Ch (6 channel board)
2: 8-Ch (8 channel board)
3: 6-Ch (6 channel board)

BOARD DIAGNOSTIC
Used for displaying the status error of each board installed in the projector:
0: PT-3f (Pan / Tilt board)
1: 6-Ch (6 channel board)
2: 8-Ch (8 channel board)
3: 6-Ch (6 channel board)

INFORMATION MENU

Lamp

Hours

Total

XXX

Partial XXX

Reset...

Information

System

Errors

Fixture

Hours

Total

XXX

Partial XXX

Reset...