2 rear panel level controls, 3 test tone level, 4 software downloading procedure – Dolby Laboratories DP524 User Manual

Page 26

Advertising
background image

5-2

5.2

Rear Panel Level Controls

Each analog output connector has a level control adjacent to it. Each analog output
is adjustable (at full scale) over a range of below 0dBu to greater than +24dBu.

5.3

Test Tone Level

The operating level for the test tone generator of the Model DP524 is -18dB
relative to full scale. This is useful when calibrating the analog outputs and also for
checking proper operation of the digital outputs.

The actual frequency of the tone is dependent upon sample rate (see section 3.5.1).

5.4

Software Downloading Procedure

In the event that a software upgrade is required, the RS-232 (J105) may be used to
download the appropriate files and reprogram the EEPROM residing in the DP524.
When this method of upgrade is desired, the necessary files will be supplied in IBM
PC compatible format. The downloading procedure is described below.

Remove all connectors to the DP524 except for the mains power.

Connect rear panel connector J105 to a standard PC serial port.

Note the position of S101-5 and S101-6. They must be restored to this
position when the software downloading is complete.

Set the baud rate select switches S101-5 and S101-6 as desired, according
to the table below:

Baud Rate

S101-5

S101-6

9600

Down

Down

19200

Down

Up

38400

Up

Down

Set rear panel switch S101-2 to the up position. As soon as this is done the
Front panel LEDs Mute, 48k, 44.1k and 32k will all be illuminated. During
the download sequence the Test LED will flash.

Software upgrades are supplied by Dolby Laboratories and include complete
instructions relating to the download procedure.

After the unit has been upgraded, move switch S101-2 back to its down
position. The unit will then reboot and begin running the new code.

Return switches S101-5 and S101-6 to their original positions.