Startup/10 hour, Drilling unit, Jt5 operator’s manual – Ditch Witch JT5 User Manual

Page 133

Advertising
background image

Service - 132

JT5 Operator’s

Manual

Startup/10 Hour

CMW

Startup/10 Hour

Drilling Unit

Check Engine Air Filter Service
Indicator

Check air filter restriction indicator before startup
and every 10 hours of operation. Change air filter
elements when air filter restriction indicator
reaches the red zone.

Location

Task

Notes

DRILLING
UNIT

Check engine air filter service indicator

Check engine oil level

DEO

Check hydraulic hoses

Check hydraulic fluid level

THF

Check pipe auto lubricator spray nozzle

optional equipment

Check tool joint compound level

TJC

Check coolant level

DEAC

Check drilling fluid pump oil level

NOTICE: Only open the air filter canister when
air restriction is indicated. Change the
elements, do not attempt to clean them.

Compressed air or water may damage
filter elements.

Tapping filter elements to loosen dirt may
damage the elements.