Prepare unit for towing, Return unit to normal operation, Sk850 operator’s manual – Ditch Witch SK850 User Manual

Page 61

Advertising
background image

Transport - 60

SK850 Operator’s Manual

Tow

CMW

®

Prepare Unit for Towing

1.

Block tracks.

2.

Engage parking brake (shown).

3.

Loosen bypass valves (shown) three turns.

Return Unit to Normal Operation

1.

Tighten bypass valves and tighten locknut to 15-18 ft•lb (20-25 N•m).

2.

Disengage parking brake.

3.

Unblock tracks.

IMPORTANT: Open bypass valves in both
front and rear pumps.

NOTICE: When bypass valves are open, unit
has no brakes.

IMPORTANT: Close bypass valve in both front and rear pumps.

t43om012w.eps

t43om030w.eps

Advertising