As needed, Sk850 operator’s manual – Ditch Witch SK850 User Manual

Page 88

Advertising
background image

SK850 Operator’s Manual

Service - 87

As Needed

CMW

®

As Needed

Change Air Filter

Change air filter when red band on indicator (1) is
visible. Replace safety element (4) every third
change of primary filter (3) or any time primary
element has become damaged.

1.

Open air filter housing at latches (2).

2.

Remove primary element (3).

3.

Wipe inside of housing and end cup (2).

4.

Insert new primary element.

5.

Latch air filter case.

6.

Reset air filter service indicator (1).

Location

Task

Notes

Change air filter

Check water separator filter

Adjust idler roller bearings

Check battery

Charge battery

TR50

Check digging chain rollers, sidebars, pins, and
bushings

Check digging chain teeth and bits

Check trencher headshaft sprocket bolts

Replace digging chain

t35om032w.eps

1

3

2

4

Advertising