Solar Electric Tank

Electric Connections
Solar electric hot water heater includes 240 VAC thermostat and 3500 watt element.
See Schematic

Connect Electric Heating Element
Before any electrical connections are made, verify water heater is full of water and valve in cold water supply line is open.

Solar water heater is supplied with single electric heating element backup system. Thermostat incorporates manual reset

temperature-limiting device. Refer to "Troubleshooting Guide" section for manual reset operation. Turn off all power

related to heating system before proceeding with electrical connections. Any and all wiring shall be sized and installed to

satisfy voltage and amperage used. Water heater must be well grounded. Green ground screw is provided at electrical

connection point for connecting ground wire. All wiring shall be done in accordance with all applicable local and state

codes.

Adjusting Thermostat Temperature Dial
Minimum potable water temperature can be changed by adjusting thermostat. Before any work is done on water heater,

disconnect all power to the water heater and heat source (solar collector) by opening the switch(s) at main electrical

circuit breaker or fuse box. Remove cover and fold insulation outward away form control. Adjust thermostat dial using

screwdriver until minimum acceptable temperature is achieved. Rotate temperature dial clockwise to increase water

temperature. Rotate thermostat dial counter-clockwise to decrease temperature setting. See Figure 6 for temperature

settings.
Thermostat has been factory preset to 120°F (49°C). Remember lower temperature settings are more energy efficient.

Replace insulation make sure control is well covered and plastic terminal shield has not displaced. Replace access panel.

Water heater is now ready for operation.