Table 2, Dual coil units electric backup units – Dunkirk H2OI Stainless Steel Dual Coil Solar Water Heaters User Manual

Page 5

Advertising
background image

5

BOTTOM SOLAR

COIL RETURN

TOP COIL

SUPPLY

BOTTOM SOLAR

COIL SUPPLY

T+P VALVE

TOP COIL

RETURN

COLD

WATER IN

HOT WATER

OUT

BOTTOM HEATING COIL

FOR SOLAR

BOTTOM COIL
3/8" ID THERMAL WELL

TOP HEATING COIL

FOR BACKUP

TOP COIL

3/8" ID THERMAL WELL

DUAL COIL UNITS

1/2" NPT RECIRC.

RETURN PORT

DRAIN VALVE

3/8" ID

THERMAL WELL

4" X 10"

ELECTRICAL BOX

TYPICAL ALL

ELECTRIC BACKUP UNITS

1.5

Heat exchanger coil outputs

Model

Max. Recovery

Max. Recovery

Water Flow

Pressure Drop

(gal/hr.)

(gal/hr.)

Through Coil

Through Coil

Top Coil

Bottom Coil

(gal./min.)

(Ft. Water)

115 Gal. Units

190

214

10.0

3.9

80 Gal. Units

180

214

10.0

3.6

60 Gal. Units

185

214

10.0

3.5

Note: All Ratings are based on 180 degree F boiler water supply and 50 degree F cold Water inlet.
In the interest of continuous improvement, specifications are subject to change without notice.

For all units with 3500 watt Electric Backup

Model First Hour Rating (gal/hr.) Continuous Rating (gal/hr.)

140 F

115 F

140 F

115 F

115 Gal. Units

73.9

80.0

15.9

22.0

80 Gal. Units

55.9

62.0

15.9

22.0

60 Gal. Units

45.9

52.0

15.9

22.0

DuAl COIl uNITS

ElECTRIC bACKup uNITS

Table 2

Advertising