East Coast Supercharging ECS Alky C7 User Manual

Page 8

Advertising
background image

The nozzle goes installed in the charge pipe after the MAF sensor. Not before. *Note
this particular picture shows an IAT Breakout Kit added.

To do so, first is mark where the hole will be before removing the charge pipe. Next is
drill hole into charge tube 3/8 diameter and clean up the hole from debris. The nozzle

has two washers included. If nozzles are going into aluminum, the rubber washers help

seal the nozzle.

First step is you must have a washer on the inside. Period. Next is insert threads from
the inside out and by hand attach the elbow. This will pull threads out more. Remove

elbow, next is install washer on the outside so it creates a sandwich with the mounting

surface. Start to tighten.. once some threads are now in the elbow, back it out and use
red/blue Loctite on the threads and install elbow again until it is snug. The trick is you

don’t want the nozzle tip to bottom out on the elbow.

Next is put some Loctite on the threads of the check valve supplied (single nozzle), and
apply some Loctite to the adapter that threads into the check valve. Attach 28 inch

hose from filter to nozzle. Your done with this part. Next is install cap onto reservoir

Advertising