ENG

Error codes

If the ECI 6DS is not working properly, the display will show an error code.

The error codes are:

Display Error

text

Description

What to do

DC FAULT LEFT DC voltage left channel

Please contact service center.

DC FAULT

RIGHT

DC voltage right

channel

DC

DC left + right channels

OVERLOAD

FAULT

LEFT

Overload of left

channel

Make sure that the + and – leads

of the loudspeaker cables are

not shorted, and that the speaker

cables are not in contact with the

chassis of ECI 6DS.

OVERLOAD

FAULT

RIGHT

Overload right channel

OVRLOAD

Overload left+right chan-

nels

TEMPERATURE Over temperature

left+right channel

The amplifier is overheated. This is

caused by either playing to loud

for a long period of time, or not

enough free space on the sides or

above the ECI 6DS.

Turn down the volume and make

sure there is enough free space

around the amplifier.

For troubleshooting please contact your local dealer or our support depart-
ment. All contact information you will find at www.electrocompaniet.no