How to power up your system
You should always power up your system in the following order:
First turn on the ECC-1, and then turn on the amplifiers.

When switching off your system
First turn off the amplifiers, and then turn off the ECC-1.

XLR configurations
XLR output:

1 = ground

2 = positive

3 = negative

Technical specifications ECC-1
The following technical data were measured on randomised test objects and are typical
data. All measurements are made at 120V / 240V // 50Hz / 60Hz

Measurements

Output impedance

100 ohm

Output level

4,5Vrms

Noise floor (0 dB gain)

< -130 dB

Frequency deviation

< 0.05 dB

Channel separation

> 110 dB

THD + N

< 0.002%

Digital/Analogue conversion

24 bit, 192 kHz

Dynamic range

120 dB

Power consumption (no load or signal)

35 W

Dimensions

Width

483 mm

Depth

389 mm

Height

105 mm including feets

Weight

9 kg

Specifications are subject to change without further notice.