Operating instructions – EZ-ACCESS PASSPORT User Manual

Page 14

Advertising
background image

Page 14 of

26

4. Guard Ramp

a. The standard VPL

is supplied with a 24” Guard Ramp which can be assembled on either end of the

platform allowing access to the VPL from either side. The Guard Ramp operation is automatic.
When the VPL rises, the ramp will fold upward providing a safety measure to help prevent
accidental travel off the platform while the VPL is moving.

5. Obstruction Detection

a. The VPL is supplied with a Safety Pan which is designed to detect an object or obstruction under

the platform and stop downward travel when it comes into contact with the Safety Pan. The VPL will
still be operational in the upward direction, but the object or obstruction must be cleared to resume
downward travel.

6. Emergency Crank

a. In the event of a loss of AC power and the batteries have been fully discharged, the VPL may be

operated up or down using a manual hand crank. This crank is attached inside the power head
cover. As an alternate, a

5/16” hex driver bit on a powered drill can be used to drive the unit up or

down. Refer to Section 17 for additional information on the emergency hand crank before using.

SECTION 16

- OPERATING INSTRUCTIONS

1. Read, understand and observe all safety warnings, notes and recommendations throughout this

manual.

Do not exceed the

VPL’s weight capacity of 750 Lbs.

Use VPL with a qualified helper if required.

Do not use VPL for anything other than lifting people and mobility equipment.

Do not operate VPL if it appears damaged.

Never tamper with or attempt to bypass any control sensors or switches. Doing so can result
in creating a dangerous situation and will void your warranty.

2. UPWARD TRAVEL:

a. Be sure to have a straight, direct path on to the Guard Ramp and Platform.
b. Move far enough onto the center of the Platform to allow the Guard Ramp to fold upward without

contacting the mobility device.

c. Ensure the mobility device and all body parts are completely on the Platform and within the Guard

Walls and off of the Guard Ramp.

d. Verify no part of the mobility device, body parts, or other items extend beyond the platform.
e. Once properly situated on the Platform, turn off power and ensure the brakes are properly set on

the mobility device. (Contact manufacturer of your particular mobility device for assistance).

f. Rotate the keyed power switch to Power On position. The

blue LED indicator light in the GREEN

background should now be illuminated.

If you want to travel up, press and hold the UP button. The VPL will operate in the upward

direction and the UP indicator light will illuminate.

g. Continue pressing the up button until the VPL stops automatically at the upper landing. The

ENTER/EXIT indicator LED light should illuminate at this time. Release the Up button.

Advertising