Maintenance, Notice – E-Z-GO FREEDOM TXT 2+2 User Manual

Page 47

Advertising
background image

39

MAINTENANCE

Read all of this manual to become thoroughly familiar with this vehicle. Pay particular attention to all Notices, Cautions, Warnings, and Dangers.

Even if the water is colorless, odorless, tasteless and fit for

drinking, the water should be analyzed to see that it does

not exceed the impurity levels specified in the table.

Hand held watering devices available at an automotive parts store, or automatic watering devices such as the one

included in the E-Z-GO Battery Maintenance Kit (P/N 25587-G01) can be used with an approved water source. These

watering devices are accurate, easy to use and allow for rapid filling. They also maintain the correct electrolyte level

within the battery cells.

The watering device should only be used if the electrolyte level is less than 1/2” (13 mm) above top of plates.

Water Purity Table

Impurity

Parts Per

Million

Color
Suspended
Total Solids
Calcium & Magnesium Oxides
Iton
Ammonia
Organic & Volatile Matter
Nitrites
Nitrates
Chloride

Clear

Trace

100

40

5
8

50

5

10

5

Hand Held Watering Device

Distilled Water

Dispensing valve consistently
fills to a predetermined level

Electrolyte Level

Single Battery Cell

Watering gun similar to the type included in the E-Z-GO

Battery Maintenance Kit

Pure Water

Valve consistently
fills to a predetermined
level

Electrolyte Level

Single Battery Cell

Automatic Watering Gun

NOTICE