MAINTENANCE

Read all of this manual to become thoroughly familiar with this vehicle. Pay particular attention to all Notices, Cautions, Warnings, and Dangers.

5 - 16

5

DO NOT overfill batteries. The charging cycle will expel electrolyte and result in component damage.
A battery being charged will ’gas’ with the majority of the gssing taking place at the end of the charging cycle. This

gas is hydrogen with is lighter than air. Water and sulphuric acid droplets will be carried out of the battery vents by

the hydrogen gas, however, this loss is minimal. If the battery electrolyte level is too high, the electrolyte will block

the vent tube and the gas will force it out of the vent tube and battery cap. The water will evaporate but the sulphuric

acid will remain where it can damage vehicle components and the storage facility floor. Sulphuric acid loss will

weaken the concentration of acid within the electrolyte and reduce the life of the battery.

Over the life of the battery, a considerable amount of water is consumed. It is important that the water used be pure

and free of contaminants that could reduce the life of the battery by reducing the chemical reaction. The water must

be distilled or purified by an efficient filtration system. Water that is not distilled should be analyzed and, if required,

filtration installed to permit the water to meet the requirements of the water purity table.

Even if the water is colorless, odorless, tasteless and fit for drinking, the water should be analyzed to see that it does

not exceed the impurity levels specified in the table.
Automatic watering devices such as the one included in the Battery Maintenance Kit (P/N 25587-G01) can be used

with an approved water source. These watering devices are accurate, easy to use and allow for rapid filling. They

also maintain the correct electrolyte level within the battery cells.

Vent Cap

Gas Vent

Vent

Expansion

Space

Plates

1/2” (13 mm)

1/4” to 3/8”

(6 mm to 10mm)

Electrolyte level should be at least

1/2” (13mm) above the plates and 1/4”

to 3/8” (6 to 10 mm) below vent

Correct Electrolyte Level

Water Purity Table