MAINTENANCE

Read all of this manual to become thoroughly familiar with this vehicle. Pay particular attention to all Notices, Cautions, Warnings, and Dangers.

5 - 22

5

PROLONGED STORAGE

Battery charger, controller and other electronic devices need to be disconnected since they will contribute to the pre-

mature discharge of batteries.
During periods of storage, the batteries will need attention to keep them maintained and prevent discharge.
In high temperatures the chemical reaction is faster, while low

temperatures cause the chemical reaction to slow down. A

vehicle that is stored at 90° F (32° C) will loose.002 of specific

gravity each day. If a fully charged battery has a specific grav-

ity of 1.275, and the battery is allowed to sit unused, it will

become partially discharged. When it reaches 1.240, which it

will do in less than twenty days, it should be recharged. If a

battery is left in a discharged state, sulfating takes place on

and within the plates. This condition is not reversible and will

cause permanent damage to the battery. In order to prevent

damage, the battery should be recharged. A hydrometer (P/N

50900-G1) can be used to determine the specific gravity and

therefore the state of charge of a battery.
In winter conditions, the battery must be fully charged to pre-

vent the possibility of freezing. A fully charged battery will not

freeze in temperatures above -75° F (-60° C). Although the

chemical reaction is slowed in cold temperatures, the battery

must be stored fully charged, and disconnected from any cir-

cuit that could discharge the battery. For portable chargers,

disconnect the charging plug from the vehicle receptacle. For

on-board chargers, disconnect the charging harness from the

batteries. The batteries must be cleaned and all deposits neutralized and removed from the battery case to prevent

self discharge. The batteries should be tested or recharged at thirty day minimum intervals.

1.100

1.120 1.160 1.200 1.240 1.280

1.140 1.180 1.220 1.260 1.300

-9

-15
-21
-26
-32
-37
-43
-48
-54
-60
-65
-71

E

L

E

C

T

R

O

L

Y

T

E

T

E

M

P

E

R

A

T

U

R

E

SPECIFIC GRAVITY ELECTROLYTE FREEZING POINT

Freezing Point Of Electrolyte

O

C

+15

+5

-5

-15
-25
-35
-45
-55
-65
-75
-85
-95

O

F

Advertising
This manual is related to the following products: