Heath Consultants Aqua-Scop User Manual

Page 23

Advertising
background image

(Figure 10)

As you can see from Figure 10, in preliminary detection the Direct Contact

Microphone is connected with the Amplifier Module and the Headset is

plugged into the jack on the Amplifier Module. The Volume is then turned

clockwise and the amplification is turned up enough so that the sound

of a leak is recognizable. The position of 4 to 6 on the volume control is

recommended for best sound intensity.

Procedure of Preliminary Detection: The point of the Direct Contact

Microphone is placed on the part of the line, which is to be checked. The

point should be abraded and firmly held against the line to insure good

contact. When the Direct Contact Microphone is firmly placed on the line,

the “Listen” control switch on the Amplifier Module is depressed. This will

complete the electrical contact between the microphone and the amplifier.

The switch should not be depressed before or while making contact, as

the noise of making contact is unpleasant to the ear. Tests are made in this

manner and sound levels for the tests compared (see Figure 11). Figure

12 is an example of the above technique in a field situation. The Direct

Contact Microphone should not be immersed in water. If a test must be

taken in deep water, use the extensions or contact the line or desired test

point with a rod or key. The tip of the Direct Contact Microphone is then

used on the rod or key.

20

Advertising