(Figure 20)

Leakage on Asbestos-Cement and Plastic Pipe

The very poor transmission of sound on this material will make other

methods for detection necessary. The efficiency of using the Direct Contact

Microphone for the preliminary localization will be diminished by the lack

of sound transmission through the line. Also, if testing fittings with direct

contact with the Direct Contact Microphone no sound of flowing water is

heard, the presence of a leak cannot be excluded. It is recommended in all

cases to check over the mains with the Ground Microphone at distances

of 3 to 6 feet.

Other Sonics

Some highly sophisticated sonic instrumentation has been developed using

sound delay techniques, computer analysis, and analysis of sound waves

on the oscilloscope. These methods are quite expensive but should be

considered where conventional sonic methods are impractical.

G. Alternate Methods of Leakage Detection

Tracer Gases

For situations where sonic testing is completely impractical, the use

of tracer gases should be considered. There are several tracer gas

systems available and the following is a brief synopsis of advantages

and disadvantages of four of these systems: