Heath Consultants Heath Volume Corrector (HVC) User Manual

Page 15

Advertising
background image

15

* FPV Mode = (Auto or fixed). Use “Auto” to calculate FPV based on the configurations of the
instrument. Use “Fixed” when using fixed factor measurement or there is a need to lock in a specific FPV
for calculation.

* Instrument Units = (US or Metric) When configured to US units the unit will display in Cubic Feet for
Volume/ PSI for Pressure/ Degrees F for temperature. When configured to Metric units the unit will
display in Cubic Meters for Volume/ KPA or BAR for Pressure/ Degrees C for temperature. Caution:
When setting to Metric, the values for Base Pressure, Zone Pressure, Base Temp and Transducer “Full
Scale” value MUST be manually converted to reflect the desired metric unit.

* Metric Pressure Units = (Bar or KPA) Select which metric unit the instrument will use for pressure.

* Display Previous Month in LCD Sequence= (Check box) This setting will add the “Total
accumulated Uncorrected volume” and “Total accumulated Corrected volume” from the entire previous
month and display it on the LCD. The LCD reading will display [“Pc” (volume)] for Previous Corrected
and [“Pu” (volume)] for Previous Uncorrected volume from the previous month. This reading will stay
the same for the month until the 1

st

of the next month is passed, then it will be updated with the totals

from the previous month.

* Display Max Day in LCD Sequence= (Check box) This setting will add the “Max Corrected volume”
accumulated in 24 hours and display the volume reading and the date that the max volume occurred. The
LCD will display [“Hd” (volume)] push the scroll button again and the next screen will be the date that
the “High day” or “Max day volume” occurred. To reset this, hold the scroll button on the “Max Day
reading” for four seconds and the reading will go to zero and the date will read [- - - - - - - -] until the next
Max day occurs.

* Previous Monthly Accumulators= (Check box) This setting will reset the Previous Monthly
Uncorrected and Corrected Accumulators back to zero.

* UnCor Vol Input = (Digital or Opto Input) Set to “Digital” for the HVC standard “Falling magnet/
reed switch index. Set to “Opto Input” if using the older style “optical” index used in the older LVC/XVC
instruments. Note: The HVC can use either input.