Heath Consultants Optical Methane Detector (OM) User Manual

Page 5

Advertising
background image

5

S

YSTEM

S

PECIFICATIONS

OMD

TM

System Specifications

Configuration:

Double - ended

Sensitivity:

1 PPM / meter CH4

Measurement Range:

1 to 200 PPM

Accuracy:

± 10% (1 to 100 PPM range)
± 20% (100 to 200 PPM range)
Above 200 PPM = Not relatively
accurate

Display Ranges:

10, 30 and 90 PPM

Self - test:

During boot – up

Calibration/Test:

Via operator, self - contained

Calibration:

Via RS-232 through software

Base - Line Compensation:

Via RS-232 through software

Display:

Back-lit 2" x 6" graphics LCD,
adjustable contrast

Operator Interface:

Sealed membrane switch overlay

Operator Alarms:
Signal:

High pitch audible with
adjustable set point, pitch
increases with concentration.
Adjustable volume.

Error:

Low pitch audible with
adjustable set point

Error alarms
provided for:

Warm-up, Low Light,
Communication Failure &
Battery low

System Power:

72 Watts @ 12 VDC

System Voltage:

12 - 16 VDC

NOTE: To avoid damage to the OMD power box, the fuse
must be removed prior to charging or jumping the battery
in the survey vehicle!