Heath Consultants Optical Methane Detector (OM) User Manual

Page 50

Advertising
background image

50

HEATH CONSULTANTS INCORPORATED
OPERATING STANDARDS - MOBILE OMD

TM

SURVEY

GENERAL SPECIFICATIONS
I. Purpose of Survey

The purpose of the survey is to inspect any portion of a gas

system, which can be driven over, or adjacent to, to detect,
classify and report leakage locations that are venting to the
atmosphere.

II. Scope

A. Portion of System to be Inspected

The mobile survey is used in any area where the
vehicle can be driven in such a manner as to place the
light path of the OMD within the plume of methane
that is venting from the ground.

B. What is Inspected

Mobile survey provides coverage of mains, associated
valves, regulators and drips, the service taps at the
main and that portion of the service line located in or
near the street, alley or area where the survey vehicle
can be driven.

III. Personnel Required

The survey is conducted by a one or two-person team.

IV. Equipment Required

A. A vehicle containing the following:

1. OMD
2. Plunger Bar
3. Combustible Gas Indicator
4. Report Forms

Advertising