3 adding additional subnets to a secure connection, 4 disabling secure connections – Lab.gruppen Bridge User Manual

Page 19

Advertising
background image

DeviceControl Operation Manual

19

Figure 6.2

Fill in “New Password” and “Confirm

8.

Password” with the same password set in
step 4. These passwords must be identical to
establish connection between DeviceControl
and NLB 60Es.

Verify that all NLB 60Es are selected.

9.

Press Set.

10.

Press OK in the Settings dialog. The secure

11.

connection is enabled.

6.1.3 Adding additional subnets to a secure

connection

Additional subnets may be added to an existing
secure connection as follows:

Enable the secure connection physically in the

1.

additional NLB 60E as described in 6.1.1.
Start DeviceControl

2.

Choose “Create a new configuration” in the

3.

Quick Start menu.
From the main window, select Settings from

4.

the File menu.
Click on the Security tab.

5.

Click on “Change authentication password” for

6.

NLB 60E
The “Change NLB 60E Password” dialog pops

7.

up.

Leave “Old Password” field empty. (No

a.

password has yet been set in the newly
added NLB 60Es).
“New Password” and “Confirm Password”

b.

are filled in with the same password set
in step 8 in 6.1.2 above. These passwords
need to be the same to establish connection

between DeviceControl and the NLB 60Es.
Verify that all added subnets are visible.

c.

Press “Deselect All” and select the new
(added) subnets only.
Press “Set”.

d.

8. Press “OK” in the Settings dialog. Secure

connection is now enabled in the additional
NLB 60Es.

You can verify that a secure connection has

been enabled by checking the NLB 60E
information log via the front panel menu
and display. Refer to the NLB 60E Operation

Manual for more information.

6.1.4 Disabling secure connections
Use this procedure if you no longer wish to have a
secure connection to the NomadLink network.

Disabling secure connection in the NlB 60E
The following steps must be repeated for each NLB
60E in the system.

Press the Select key on the NLB 60E front

1.

panel until the Configuration menu appears in
the display. Press “OK”.
Press Select until Security menu appears. Press

2.

“OK”.
Press “OK” for “Secure Conn.”.

3.

Press on Adjust/Set until “Disable” appears.

4.

Press “OK” to confirm.

The previously set password in the NLB

60E is reset (deleted) when the secure
connection is disabled. A new password
must be set in the NLB 60E when re-enabling

a secure connection.

Disabling secure connection in DeviceControl

Start DeviceControl

1.

Choose “Create a new configuration” in the

2.

Quick Start menu.
Select “File” and then “Settings…” from the

3.

menu bar.
Click on the Security tab.

4.

Uncheck the “Enable Secure Connection” box.

5.

Type password in the “Disable secure

6.

connection” dialog.

Upon completing step 6 above, the pass-
word is reset (deleted). A new password

reference section 6

Advertising