SUNTUF® Technical Guide

Profile: SUNTUF® 100

©PALRAM Industries. All rights reserved.

Profile Drawing



Profile Dimensions

Profile

(mm)

Thickness

(mm)

Length

(m)

Overall width

(mm)

Cover Width

(mm)

Side-Lap

( % )

250 / 40

1.0 – 2.0

1.5 - 11.8

1063

1000

5.9


Load / Span Data

Load

(kg/m²)

Maximum Roof Span (mm)

1.0 mm

1.2mm

1.5 mm

2.0 mm

Mid Field

End Field

Mid Field

End Field

Mid Field

End Field

Mid Field

End Field

50

1800

1350

1850

1390

1900

1430

2000

1500

75

1600

1200

1650

1240

1700

1280

1800

1350

100

1450

1090

1500

1125

1550

1160

1650

1240

125

1350

1010

1400

1050

1450

1090

1550

1160

150

1250

940

1300

975

1350

1010

1450

1090

 The specified dimensions do not supersede the requirements of local construction codes.
 The maximum purlin spans are based on continuous beam calculation model and practical testing.
 The criterion for allowed deflections is L/20.
 The mentioned load refers to both wind and snow loads.
 Minimum recommended slope – 10%.
 For vertical application spans can be increased by 10%.

Panel Length

 Maximum recommended panel length - 7.0 m.

 Recommended longitude overlap of 200mm above purlin.

 Each panel to extend 100mm over the fixings line on the purlin.

 Panels should overhang Min. 50mm and Max. 150mm beyond the last fixings line.

Curved Roof

Minimum curving radius 16.0 m.