SUNTUF® Technical Guide

Profile: SUNTUF® 100

©PALRAM Industries. All rights reserved.

Positioning

 Make sure the UV protected side faces out.

 Side-lap of SUNTUF panels must be installed against the primary direction of rain.

 The SUNTUF panels must be located and installed without any stresses.

Do not pull, stretch or force the sheets when the profiles are not perfectly matched.


Fastening

 Apply sealing tape over the SUNTUF panel side-lap corrugation crests, where covered by the next panel.

 Apply sealing tape along the bottom and top End-lap (if there is), along screws centerline or two tapes on

both sides of screw centerline.

 Pre-drill 10mm holes at crests where screws are positioned.

 Start fastening the screws from the first side-lap (left) through the pre-drilled holes (2).

 Start fastening the screws on the lower edge purlin (End-lap), on each corrugation crest (1).

 Fasten screws at the internal and upper edge purlins, at each corrugation crest, starting at the same side

(1, 2).

Do not over-tighten!

Fasten the stitching screws at every 300 mm (3).

Fastening Location

(1)

(2) (3)

Screws and Washers Specification

 Crest fixing: Self-drilling 5.5mm x 75mm (3") screw + matched metal crest rider (Storm washers) with

EPDM gasket.

 Side Stitching: 5.5mm x 25mm (¼”x1") Stitching Screws (Grommet seals) with EPDM seal.