Portable Winch AC Electric pulling/lifting winch PCT1800-60Hz-P User Manual

Page 21

Advertising
background image

21

AFTER EACH LOWERING OPERATION, IT IS IMPERATIVE TO CHECK

ROPE CONDITION.

NEVER GO OVER THE RATED LIFTING CAPACITY (250 KG (550 LB))

SINGLE LINE.

NEVER BYPASS THE ROPE GRABBING SYSTEM.

NEVER SHOCKLOAD THE SYSTEM.

BEWARE OF ROPE SNARLS WHILE LOWERING. IF ROPE GETS

TANGLED, PULL ON ROPE, WHICH WILL START THE MOTOR, UNTIL CLEARED.

DO NOT TOUCH THE CAPSTAN DRUM IMMEDIATELY AFTER OPERATION

AS IT WILL GET HOT AND BURN BARE SKIN.

When you stop lifting with the PCT1800 AC Electric Portable Capstan Pulling/Lifting Winch

TM

, the

rope grabbing system engages, therefore, holds a load in position and keeps the rope under
tension. To release it, follow these steps:

1. Figure 1, no. 1: Pull horizontally (and gently) on the pulling rope to engage the motor, this

will release the tension applied by the rope grabbing system on the pulling rope;

2. Figure 1, no. 2: Pull gently on the rubber handle of the rope attached to the rope grabbing

system; this will disengage the system;

DO NOT COMPLETELY DISENGAGE THE ROPE GRABBING

SYSTEM, IN CASE OF EMERGENCY, SIMPLY LET THE RUBBER HANDLE GO, THE
SYSTEM WILL RE-ENGAGE.

NEVER LET THE PULLING ROPE SLIDE SUDDENLY IF A LOAD IS

SUSPENDED.

3. Figure 1, no. 3: Slowly payout the pulling rope (push it towards the winch if necessary -

this may occur if you have four wraps of rope on the drum and a light load) while keeping
the rope grabbing system slightly open;

4. Figure 1, no. 4: Release the tension applied to the rubber handle, this will re-engage the

rope grabbing system. You can now let go the pulling rope and grab it further;

5. Repeat steps 1 to 4 until the load is at desired position or completely lowered;

Advertising
This manual is related to the following products: