10 DESCRIPTION OF CONTROLS

overload indication operates on input signal levels prior to the Limiter processing,
regardless of the gain setting, in order to provide input overload warning at all times.

INPUT GAIN display

Displays effective gain at all times and allows settings to be typed in manually.

Pre-Process Section

ATTACK fader

Provides setting of attack timing from 0.05mS to 1mS (ref. 10dB gain change).

RELEASE fader

Provides adjustment of release timing from 0.05mS to 1.038 seconds (ref. 10dB
gain change).

SOFT KNEE fader

Adjusts the soft limiting threshold from 0dB (hard limiting) to 10dB (maximum soft

limiting).

GAIN REDUCTION meter

Permanently displays the total peak gain reduction due to Pre-Process dynamic
gain control action.

AUTO GAIN button

Switches in an additional long-term gain process, providing automatic gain scaling
compensation to accommodate wide input programme level ranges.

SAFE MODE button

Switches the plug-in into Safe Mode, which employs the Enhance section to control
peak levels at all times. When this is not selected, the plug-in is considered to be in

‘Normal Mode’.