Installation of restraint, Onnect, Attery – Southbend P32D-171 User Manual
Page 13: Ections, Nly)
OWNER’S MANUAL 1199790 REV 0 (6/14)
PAGE 13
OF 46
I
NFRARED
B
ROILER
Figure 7
Be sure all controls are turned off prior to disconnecting. After reconnecting, be sure all controls are turned off and all
pilots are lit.
NOTICE
Adequate means must be provided to limit the movement of the appliance without depending on the connector and
the quick-disconnect device or its associated piping to limit the appliance movement.
The restraining means should be attached to a frame member on the back of the unit.
I
NSTALLATION
Installation of Restraint
S
TEP
4
:
C
ONNECT
B
ATTERY
S
ECTIONS (
O
VEN
B
ASE
O
NLY)
If the unit is part of a battery, and the battery was shipped partially disassembled, connect the battery sections using the
following procedure.
1. Remove valve panels from all sections. Mark them so that they can be returned to their respective section.
2. Position the center section of the battery and carefully level that unit. Use a long spirit level four ways; across front
top rail and the rear edge, and along each side edge.
3. If not already in place, attach pipe-union to front manifold of the battery. Screw it in far enough to be able to slide the
adjacent section into position.
4. Bring up adjacent section and level it using the same method and by using the center unit as reference. Match front
rails and rear edge. When a battery is set on a masonry base and legs are not used, shims may be used. Special
attention should be given to griddle tops to allow proper drainage.
F
G
H
I
B
C
E
D
A